中文版 Links
New Product Recommendation
 
 
UPS
 
N+X modularization MP series 10-200KVA
N+X low frequency online CP series 10-400KVA
online low frequency DP series 3-20KVA
Online high frequency UPS RC series (rack mount) 1-10KVA
N+1 online high frequency D series 6-20K
Online high frequency E series 1-10KVA
online high frequency D series 1-3KVA
Line-interactive A series 1-3KVA
Off-line V8 series
Offline NT series
Offline V- Power series
Online high frequency D1~10KVA(Smaller Size)
 
 
Electric power DL series 2-60KVA
 
Inverter
 
Electric power industry 0.5-40KVA
Telecommunication industry 0.5-10KVA
 
Free-maintenance lead-acid battery
 
GH series long life battery
NP series 12V battery
6-GFM series 12V battery
6-GFM-X series 12V battery
GFM series 2V battery
 
 
 
 
 
 
UPSilon2000 monitor software
Battery online monitor
 
 
 
- Electric power DL series 2-60KVA
Products
Basic Features :

Basic Features
DL series electric power UPS is specially designed for Chinese power grid environment. DC power supply directly matches DC power supply of power system 110/220 VDC. With DSP control technology, advanced IGBT module and very wide input voltage range, the UPS gets easy operation and management and high efficiency in low cost. It can protect the whole network of hardware facilities, operation program and data, and the data transmission route. It is a highly reliable, intelligent power supply system with complete function.

Applications
● Power Factory & Power System
● Industrial Automatic Control/Office Automation
● Stock Exchange/Post & Telecommunication
● Television and Broadcasting/National Defense System/Petrochemical

Basic Performances
1. Multiple CPU intelligent control
Advanced multiple CPU intelligent control is one digital software processed by microprocessor, can precisely and integrally control UPS data, and provide with enough calculation capacity, so that UPS can be under the best operation at any time.
2. Advance IGBT inverted technology
Combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), the technology can reduce systematic noise and power loss, so that customer can obtain hi-quality power output and optimized efficiency under each operation load.
3. Advance phase-balanced technology
With most advanced phase-balanced technology now, it features best stability, even if loss-phase, it still operates at normal condition, especially in some worse power supply environment.
4. 100% unbalanced three-phase output load
100% unbalanced three-phase output load and non-linear most suitable. Using rate capacity needn't reducing the amount of machine is available when three-phase unbalance, single or double phase loaded.
5. Perfect input and output loss-phase protective function
Perfect input and output loss-phase protective function, will be panic itself when the phase unbalance so that protect from loaded equipment and UPS itself.
6. Intelligent by-pass switch
UPS can automatically monitor public power voltage under by-pass circuit mode, if input voltage exceeds rated value -20%~+15%, it shall automatically terminate its voltage output so as to protect form loaded equipment and UPS itself.
7. Perfection protection
The protection will protect short circuit when the input AC is over-voltage, under-voltage, Forecast-warning if low cell and over-temperature inside that improve the stability and reliability of system operation.
8. Static switches with special design
Static switches with special design provide with truly non-stop operation, owing to isolation transformer on output, it will be achieved current isolation. Based pm the static switches design in circuit, will ensure that non-stop on output voltage in any way. That protects the safety of user's load in normal work.
9. Battery Switch-on Function
The device features its battery switch-on function, at no public power supply for UPS device, the battery can supply with power alternatively, and then provide with stable AC power output, and thus more conveniently provide the customer wit flexible solution for power supply.

Features
● Double conversion online working mode
● Advanced IGBT power device
● DC 220VDC or 110VDC input
● 100% unbalanced three-phase load can be operated continuously
● Standard power machine cabinet design
● DC Screen is isolated from main power completely
● Digital control Static switch with zero interruption transfer
● Voltage stabilization function on the bypass mode, manual bypass function
● LCD, LED display monitor interface in many languages
● Intelligent test and Rs232/485 monitor

Specification
I. DL2K~20K (Single phase input and single phase output)

Model

DL2K

DL3K

DL6K

DL10K

DL15K

DL20K

Capacity(VA/W)

2K/1.6K

3K/2.4K

6K/4.8K

10K/8K

15K/12K

20K/16K

AC Input voltage

Single phase with two Lines +ground wire ,220V±25%

AC output voltage

220V±0.5%

DC voltage

220V(110V)

DC voltage range

180V~300V(90V~150V)

Noise

≤52dB(Distance 1m)

≤60dB(Distance 1m)

Size(W×D×H) (mm)

530×264×592

620×343×725

620×343×995

Or 800×600×2260

Weight (kg)
(exclusive battery)

85

110

130

205

230

260

AC input

Frequency

50Hz/60Hz±10%

Power factor

≥92%

AC output

Frequency

50Hz/60Hz±0.05%(DC Supply)

Wave form

Pure sine wave, Distortion factor <3% (linear load), <5%( non-linear load)

Unbalanced voltage

Balanced Load≤1%, Unbalanced Load≤3%

Phase angle

Balanced Load≤1°, Unbalanced Load≤3°

Dynamic transient range

Output 0~50%~100%, ≤3%, recovery time ≤10ms

Overload capacity

125%≥10min, 150%≥20s

Peak value

5:01

Transfer time

True online zero switch

Efficiency

AC input to AC output

>91%

Warning sound

DC discharge

Main power fails, buzz once every 4 seconds

DC low voltage, buzz once every 1 second

DC discharge finish, buzz continuously

Fault abnormity

Buzz continuously

Internal protection device

DC

DC low voltage, automatic shutdown;  no-fuse switch protection

Overload capability

110~150% overload, switch to bypass, automatic recovery

Over Temperature

Internal temperature>85℃, automatically jump to bypass mode

Output short circuit

Current limiting, Automatic shutdown, fuse and no-fuse switch protection

UPS abnormity

Automatically jump to bypass mode and start main power

LCD display

Input voltage, Output voltage, Frequency, DC voltage, Output power efficiency (%)

System performance

MTBF system function

300,000 Hours

Working environment

-10℃~50℃, 0%~93% (No condensation), altitude≤3000m

Software interface

Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux

Others

Dustproof and moisture proof, Isolation transformer, Thunderbolt surging wave absorption

II. DL6K~DL60K (Three phase input and single phase output)

Model

DL6K

DL10K

DL15K

DL20K

DL30K

DL40K

DL50K

DL60K

Capacity(VA/W)

6K/4.8k

10K/8k

15K/1k

20K/16k

30K/24k

40K/32k

50K/40k

60K/48k

AC input voltage

Three phase with four Lines +ground wire, 380V±25%

AC output voltage

220V±0.5%

DC voltage

220V(110V)

220V

DC voltage range

180V~300V(90V~150V)

180V~300V

Noise

≤60dB (distance 1m)

≤65dB (distance 1m)

Size(W×D×H) (mm)

620×343×995

550×600×1135

650×700×1510

(650×700×1510)×2

/(800×600×2260) ×2

or 800×600×2260

Weight(kg)
(exclusive battery)

150

195

220

270

460

520

620

710

AC input

Frequency

50Hz/60Hz±10%

Power factor

≥92%

AC output

Frequency

50Hz/60Hz±0.05%(DC Supply)

Wave form

Pure sine wave, Distortion factor <3% (linear load), <5%( non-linear load)

Unbalanced voltage

Balanced Load≤1%,Unbalanced Load≤3%

Phase Angle

Balanced Load≤1°,Unbalanced Load≤3°

Dynamic transient range

Output 0~50%~100%, ≤3%, recovery time ≤10ms

Overload capacity

125%≥10 Min,150%≥20s

Peak value

5:1

Transfer time

True online zero switch

Efficiency

AC input to AC output

>91%

Warning sound

DC discharge

Main power fails, buzz once every 4 seconds

DC low voltage, buzz once every 1 second

DC discharge finish, buzz continuously

Fault abnormity

Buzz continuously

Internal protection device LCD panel

DC

DC low voltage, automatic shutdown, no-fuse switch protection

Overload capability

110~150% overload, switch to bypass, automatic recovery

Over temperature

Internal temperature>85℃, automatically jump to bypass mode

Output short circuit

Current limiting,Automatic shutdown,fuse and no-fuse switch protection

UPS abnormity

Automatically jump to bypass mode and start main power

LCD display

Input voltage, Output voltage, Frequency,
DC voltage, Output power efficiency (%)

System performance

MTBF system function

300,000 Hours

Environment request

-10℃~50℃, 0%~93% (No condensation), altitude≤3000m

Software interface

Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux

Others

Dustproof and moisture proof, Isolation transformer, Thunderbolt surging wave absorption

III. DL6K~DL60K (Three phase input and three phase output)

Model

DL6K

DL10K

DL15K

DL20K

DL30K

DL40K

DL50K

DL60K

Capacity(VA/W)

6K/4.8k

10K/8k

15K/12k

20K/16k

30K/24k

40K/32k

50K/40k

60K/48k

AC input voltage

Three phase with four Lines +ground wire, 380V±25%

AC output voltage

Three phase with four Lines +ground wire,380V±1%

DC voltage

220V (110V) +25%/-18%

220V+25%/-18%

Noise

≤53dB (distance 1m)

≤60dB (distance 1m)

Size(W×D×H) (mm)

600×800×2260

Weight (kg)
(exclusive battery)

260

280

310

340

490

540

650

720

AC input

Frequency

50Hz/60Hz±10%

Power factor

≥95%

AC output

Frequency

50Hz/60Hz±0.05 %( DC supply)

Overload capacity

125%≥10 Min, 150%≥20s

Unbalanced voltage

Balanced Load≤1%, Unbalanced Load≤3%

Wave form

Pure sine wave, Distortion factor <3% (linear load), <5%( non-linear load)

Peak value

5:1

Transfer time

0ms

Efficiency

AC input to AC output

≥95%

Warning sound

DC discharge

DC low voltage, buzz once every 1 second

DC discharge finish, buzz continuously

Fault abnormity

Buzz continuously

Internal protection device

 LCD panel

DC

DC low voltage, automatic shutdown, no-fuse switch protection

Overload capability

110~150% overload, switch to bypass, automatic recovery

Over temperature

Internal temperature>85℃, automatically jump to bypass mode

Output short circuit

Current limiting,Automatic shutdown, fuse and no-fuse switch protection

UPS abnormity

Automatically jump to bypass mode and start main power

LCD display

Input voltage, Output voltage, Frequency, DC voltage, Output power efficiency (%)

System performance

MTBF system function

300,000 Hours

Environment request

-10℃~50℃, 0%~93% (No condensation), altitude≤3000m

Software interface

Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux

Others

Dustproof and moisture proof, Isolation transformer, Thunderbolt surging wave absorption

 

Home | About Us | Netion News | Products | Solutions | Q/C | Win-win Cooperation | Contact Us | 中文版
  • Products
  • News
2011 ©  NETION ELECTRONIC CO.LTD All Rights Reserved