中文版 Links
New Product Recommendation
 
 
UPS
 
N+X modularization MP series 10-200KVA
N+X low frequency online CP series 10-400KVA
online low frequency DP series 3-20KVA
Online high frequency UPS RC series (rack mount) 1-10KVA
N+1 online high frequency D series 6-20K
Online high frequency E series 1-10KVA
online high frequency D series 1-3KVA
Line-interactive A series 1-3KVA
Off-line V8 series
Offline NT series
Offline V- Power series
Online high frequency D1~10KVA(Smaller Size)
 
 
Electric power DL series 2-60KVA
 
Inverter
 
Electric power industry 0.5-40KVA
Telecommunication industry 0.5-10KVA
 
Free-maintenance lead-acid battery
 
GH series long life battery
NP series 12V battery
6-GFM series 12V battery
6-GFM-X series 12V battery
GFM series 2V battery
 
 
 
 
 
 
UPSilon2000 monitor software
Battery online monitor
 
 
 
UPS - N+X low frequency online CP series 10-400KVA
Products
Basic Features :

        With dual conversion true online design and digital technology, this kind of UPS has perfect protection and high reliability.
        1. Inverter adopts DSP, MCU and DDC digital vector control technology to commend each specification and control them completely.
        2. Integrating advanced IGBT and PWM to decrease the system noise and wastage of the electric power and to make sure customers can obtain high-quality output voltage and the upmost benefit under various loads.
        3. Due to dual conversion and pure online sine wave output, the UPS can provide low distortion and pure sine wave power supply and the optimal power guarantee for the users' load devices both on main mode and battery mode.
        4. It is with output isolation transformer to ensure the load and public electricity to be isolated completely. There is no DC in the load for the UPS with isolation transformer, which can effectively protect computer, network, and communication devices from damaging of DC. Besides, for the nonlinear load, it can improve the load capability of the machine and with good compatibility. 
        5. Automatic frequency /corresponding synchronous function avoid skipping frequency to influence the devices.
        6. With perfect protections: AC input low and over voltage protections, output low and over voltage protections, output overload and short circuit protections, low battery protection, and over temperature inner of machine protection to ensure the stability and reliability of the system running.
        7. Using the big power IGBT makes the inverter with the strong ability of overload and resistant impact, and enhances the adaptation to the electric environment.
        Flexible parallel technology is fit for various loads, 1+1 parallel, N+1 parallel running;
        Each UPS in parallel is working alone and synchronous track will be adjusted to optimality ( phasic difference less than 0.50 ). The UPS can Share the load precisely and when the inverter break down, the failure UPS will shut off automatically from the parallel system to ensure that the parallel system can provide high quality AC power supply to the load. The circumfluence of the parallel system is almost zero and current imbalance is less than 2%.
        Multi-UPS parallel system: It allows the users to parallel 8 pieces of UPS at the most. Advanced monitor and DSP digital control technology makes the parallel system as easy as unit UPS and all the UPS are equal, no primary and secondary relation and it's the true equality. If you have bought one similar unit of UPS, when you need to increase the capacity or enhance the reliability, you can extend it to '1+1' parallel system easily and can continue to extend it to N+X multi-UPS system.

        System is through strict tests of short circuit and 2KVA high voltage isolation.

        Full digital control technology makes the whole unit more precise, prompt, reliable and stable.

        Strong intelligent monitor function can provide RS232, dry contact and parallel interface.

        UPS power supply environment monitor system, with the international advanced technology, develops intelligent unit and monitor management software and provides users with professional, complete, practical and reliable power monitor project, which enable the intelligent network to manage the UPS system promptly and reliably. UPS convergent monitor managing software can control the UPS everywhere in the world and inform a huge UPS power network monitor managing system.
        Monitor software features:
        1. Face single user real-time monitoring;
        2. Face large-scale WAN centralized management real-time monitoring.
        Choosing 12 impulses to correct input power factor effectively and restrain the pollution caused by UPS.

Specification

1) Rectifier

 

1.Rectifier input

 

 

Model

10KVA

20KVA

30KVA

40KVA

60KVA

80KVA

 

100KVA

120KVA

160KVA

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity (KW)

8

16

24

32

48

64

 

80

 

96

144

180

225

270

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single phase max. current(A)

19

38

57

76

114

152

 

190

 

228

304

379

475

570

760

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Work mode and principle

Supply power online, static bypass switch ('0'time transfer), double conversion technology, output isolated completely

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

 

 

0.8/0.9(12脉冲) / 0.95(加有源滤波器)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

 

 

 

 

3 phase + N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal voltage

 

 

 

 

 

380VAC±25%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal frequency

 

 

 

 

 

50/60Hz±10%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input current harmonic

 

 

 

 

 

 

5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Soft start

 

 

 

 

 

0~100% 5sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Rectifier output

 

 

 

Model

10KVA

20KVA

30KVA

 

40KVA

60KVA

80KVA

100KVA

120KVA

160KVA

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. output voltage

 

 

 

432

 

 

 

446

 

 

459

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Microcomputer setting

 

 

 

 

 

 

6~30A(adjustable)

 

 

 

 

 

 

 

 

 

 

 

 

 

charge current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2) Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

10KVA

20KVA

30KVA

 

40KVA

60KVA

80KVA

100KVA

120KVA

160KVA

 

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. discharge current(A)

28

56

85

 

113

169

225

282

338

461

 

576

 

700

 

840

1120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of battery

 

 

 

12 V32 pcs or2V192 pcs

 

 

12V33pcs or

 

12V34pcs or 2V204 pcs

 

 

 

(single group)

 

 

 

 

 

2V198 pcs

 

 

 

 

Nominal battery voltage

 

 

 

 

384VDC

 

 

 

396VDC

 

 

408VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Float charge voltage

 

 

 

 

432VDC

 

 

 

446VDC

 

 

459VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charge current

 

 

 

 

 

 

6A~30A(adjustable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

3) Inverter

 

 

Model

10KVA

20KVA

30KVA

40KVA

60KVA

80KVA

 

100KVA

120KVA

160KVA

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated capacity (KW)

8

16

24

32

48

64

 

80

 

96

 

144

 

180

 

225

270

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

single phase/three phase+ N+G

 

 

 

 

 

three phase+ N+G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal voltage

 

220/380VAC±1%

 

 

 

 

 

 

 

380VAC±1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal frequency

 

 

 

 

50/60Hz±0.5%(battery mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output power factor

 

 

 

 

 

 

0.8/0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency stability: out-sync

 

 

 

 

 

 

 

±0.5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency stability: synchronize

 

 

 

 

 

 

 

±2%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Peak factor

 

 

 

 

 

 

3:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output wave

 

 

 

 

 

 

Sine wave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total harmonic distortion

 

 

 

 

Linear load<3%; Non-linear load<5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic load voltage transient

 

 

 

 

 

 

 

±4%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instant recover time

 

 

 

 

 

 

 

10ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Balanced load voltage

 

 

 

 

1%; <±5% (unbalanced load voltage)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload capacity

 

 

 

 

125%30min,150%1min,>150% 300ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter efficiency, load 100%

 

 

 

>93

 

 

 

 

 

 

 

 

 

>96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4) Bypass

 

 

Model

10KVA

20KVA

30KVA

40KVA

60KVA

80KVA

100KVA

120KVA

160KVA

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

single phase/three phase+ N+G

 

 

three phase+ N+G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal voltage

 

 

 

 

 

380VAC±15%

 

 

 

 

 

 

 

 

 

 

 

Nominal frequency

 

 

 

 

 

50/60Hz±10%

 

 

 

 

 

 

 

 

 

 

 

 

Inverter/Bypass (transfer time)

 

 

 

 

 

 

0ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5) System

 

 

Model

10KVA

20KVA

30KVA

 

40KVA

60KVA

80KVA

100KVA

120KVA

160KVA

200KVA

250KVA

300KVA

400KVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication interface

 

 

 

 

Rs232, Rs485, Dry contact, Intelligent Slot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Work temperature

 

 

 

 

 

 

 

0~40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative humidity

 

 

 

 

 

0%~90%(non-condensing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation altitude (max)

 

 

 

1000m (1% power lost as increase 100m, 4000m max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool mode

 

 

 

 

 

 

Forced ventilation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise

 

 

 

 

48~65dB

 

 

 

 

 

 

 

 

53~68dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MTBF

 

 

 

 

 

 

300000 hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection grade

 

 

 

 

 

 

 

IP20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabinet color

 

 

 

 

 

 

White or Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input cable

 

 

 

 

 

 

Button/Rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Easy-maintenance

 

 

 

 

 

 

Front/Up/Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimension W×D×H(mm)

 

420×800×900

 

 

560×700

660×800

1200×860

 

1800×1200×1900

 

 

 

 

 

×1140

×1550

 

×1680

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WeightKG

120

140

175

 

210

350

400

550

 

650

1080

1200

 

1500~2500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input component

 

 

 

 

 

 

Connection terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output component

 

 

 

 

 

 

Connection terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 
Home | About Us | Netion News | Products | Solutions | Q/C | Win-win Cooperation | Contact Us | 中文版