中文版 Links
New Product Recommendation
 
 
UPS
 
N+X modularization MP series 10-200KVA
N+X low frequency online CP series 10-400KVA
online low frequency DP series 3-20KVA
Online high frequency UPS RC series (rack mount) 1-10KVA
N+1 online high frequency D series 6-20K
Online high frequency E series 1-10KVA
online high frequency D series 1-3KVA
Line-interactive A series 1-3KVA
Off-line V8 series
Offline NT series
Offline V- Power series
Online high frequency D1~10KVA(Smaller Size)
 
 
Electric power DL series 2-60KVA
 
Inverter
 
Electric power industry 0.5-40KVA
Telecommunication industry 0.5-10KVA
 
Free-maintenance lead-acid battery
 
GH series long life battery
NP series 12V battery
6-GFM series 12V battery
6-GFM-X series 12V battery
GFM series 2V battery
 
 
 
 
 
 
UPSilon2000 monitor software
Battery online monitor
 
 
 
UPS - Line-interactive A series 1-3KVA
Products
Basic Features :

      Outstanding reliability: Excellent line-interactive design, large batch production and continuously improved quality result in the high reliability of A-Smart UPS. Its annual average faulty rate is less than 3%.
      High performance power management: The data are more valuable than the computer itself 3 months after it is purchased, especially network files servers. All the valuable date will be lost immediately if power stops, and the saved data will be possibly destroyed too. The best choice to save the data well and improve the productivity is to be provided with A-Smart UPS.
      If the interrupted time has direct effect on your business, the perfect equipment is necessary. Because it provides power protection f the files server, microcomputer, UNIX central server, internet hub, telecommunication system and other important devices.
      A-Smart UPS will continue to protect your data through the battery supply while the power is interrupted. It will automatically store the data and shut down the system when battery is too low in reserve by the optional monitor software and accessories, no matter anyone is here or not.
      A-Smart UPS can protect the hardware and prolong the system life with non-stop voltage through auto voltage regulated, without switching to battery mode.

 

Function
      Intelligent battery management system-prolong the battery life 
      The reliability is from the precise battery charging system and the automatic battery test with load. Intelligent battery management system is with the over battery protection .Besides, it can prolong the battery life. Alarming before the battery is used up.

      Sine wave output is suitable for sensitive load
      The Sine wave output can ensure the compatibility with all loads.

      SNMP accessory slot completely supervises UPS networks management according to your demand. 
      A-Smart UPS includes SNMP slot that can install internal SNMP card(optional) for upgrade A-Smart UPS management  of  network.

      Line-interactive design has the amazing functions and reliability
      Innovative line-interactive A-Smart UPS uses the DC to AC power inverter battery charger during the normal operation. So it gives you better and wave-filtered performance as well as higher reliability with more compact components. Besides, the rate of efficiency of line-interactive topology is approximately 98%, in contrast with most of other on-line UPS’ efficiency is just 70%, and the high efficiency lessen heat loss so as to improve the reliability, because the excess heat from an on-line UPS will damage batteries and decrease reliability.

      User-Friendly online hot-swap battery replacement system
      Saving time and expense of returning UPS battery to the factory for service, you can replace the batteries safely and easily while the systems is running, put the replaced exhausted batteries in a reusable box, and return them to a recycling center or back to Netion.

      Network interface ports of line-interactive designed UPS add automatic safe system shutdown
      This is the second important step to protect the networks besides installing a A-Smart UPS. Power failures may occur at night, on weekends, or while the system administrator is out. So the auto shutdown system is necessary. All the A-Smart UPS via intercommunication port carry out the automated safe shutdown, which can be used in many popular operating systems , for instance, Novell, IBM, Microsoft, Banyan, UNIX, and so on. Power management and power-diagnosed problems can be checked by using Upsilon 2000 UPS monitor software.

Protection
Lighting and surge protection shields hardware
As the endurance for the lightning of the A-Smart UPS reaches IEEE6 2.41 category A standard, the suppression function of the A-Smart UPS is better than other suppressors.

Network-grade line conditioning prevents glitches
Non-stop EMI/RFI filters prevent errors from line noise without the need for additional external conditioners.

Regulate the over voltage automatically
The UPS can operate under the high voltage ( the most to 290V) without unnecessary battery drain.

Load and battery meters keep UPS in control
The load meter prevents exceeding UPS Capacity. And the battery meter reports the line voltage and battery capacity so that you will know how much time left before batteries are depleted. There will be alarm when batteries are low, so you have time to save data and shut down the system.

Regulate the over low voltage automatically
The UPS can operate under the low voltage (the least to 145) without unnecessary battery drain.

Battery replacement warning prevents malfunctions
A-Smart UPS automatically has a self-test every one week, which ensures you get the alarm to degraded batteries before they are worn out. Through software or pushing the button on the UPS, you can have a UPS self-tested anytime.

Informative LED display shows status clear at a glance
You can instantly assess the status of the power and the A-Smart UPS without even pushing a button, as bar charts and status indicators are simple to use and easy to understand. Visible and audible alarms warn you the fault conditions.

Specification

A-Smart

1000VA

1000VA-XL

2000VA

2000VA-XL

3000VA

3000VA-XL

Input volt. range

145~290Vac

Output volt. range

192~253Vac

Input protection

Circuit breaker

Frequency

50/60Hz±5%

Transfer time

2~3.5ms (typical load)

Output capacity

1000VA/700W

2000VA/1400W

3000VA/2100W

Output volt.
(Battery mode)

230±5%Vac

Output freq.
(Battery mode)

50/60±0.1%Hz

Waveform
(Battery mode)

Sine wave

Protection

Overload, short circuit, low voltage protection

Battery type

12V/12AH*2
12V/7AH*3

12V/100AH

12V/17AH*4

12V/100AH

12V/17AH*4

12V/100AH

DC voltage

24V/36V

24V/36V/48V

48V

48V

Recharge time

3~8hours

12hours

12hours

Backup

time

Full load

12/7min

2/4/6hours

20min

2.5hours

10min

1.5~2hours

Half load

30/16min

4/8/12hours

50min

5hours

25min

3~4hours

Communication interface

Rs232

Working temperature

0~40°C

Store temperature

-15°C~+45°C

Dimension(D*W*H)(mm)

Tower

216×170×439

432×196×546

Rack mount

480×410×137

480×460×137 (standard model 2/3K need to be installed battery group externally)

Net weight (Kg)

18.5

15.5

46.8

32

50.3

38